Model No: SV
Marka: Brando
Supply Voltages: 3.5v, 4.5v, 6v, 12v, 24v
Boby Material: Plastic
Way Number: 2 Way, 3 Way
Product Name: Solenoid Valve
Electrical Connection: Flying Leads
Service Life: About 180000 Times
Function: Normally Closed, Normally Open
Packaging: Plastikowa torba, pudełko, karton, paleta
wydajność: 100000 pcs per month
transport: Ocean,Land,Air
Place of Pochodzenia: Ningbo Chiny
Wsparcie: 20000 pcs per week
Certyfikat: CE
Porta: Ningbo,Guangzhou,Shanghai
Rodzaj płatności: L/C,T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CFR,CIF,EXW
Miniaturowy zawór elektromagnetyczny powietrza medycznego 5 V 6 V 12 V.
Zastosowania miniaturowych zaworów elektromagnetycznych BRANDO SV:
1. Urządzenia medyczne: ciśnieniomierz, masaż powietrzny, monitor pacjenta itp.
2. Masaż Sprzęt zdrowotny: masaż stóp, fotel do masażu, masaż głowy i oczu, łóżko do masażu itp.
3. Urządzenia gospodarstwa domowego: aparat zapobiegający chrapaniu, poduszka pamięciowa, ekspres do kawy, oczyszczacz wody itp.
4. Części kuchenne i łazienkowe, pielęgnacja ciała, wykrywanie i analiza gazu, zastosowania rolnicze, maszyna do rozpraszania zapachów itp.
BRANDO Seria SV miniaturowe zawory elektromagnetyczne:
|
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SV117-3.8 | 3.8 |
≤260 |
≤0.988 |
3-4.5V | 18±2 | ≤15mmHg / Min | 500CC /<10S | ≥180000 |
SV117-7.2 | 7.2 |
≤500 |
≤3.6 |
6.5-7.9V |
18±2 |
≤15mmHg / Min |
500CC /<10S |
≥180000 |
|
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SV122-4.5 | 4.5 |
≤300 |
≤1.35 |
3.5-5.0V | 20±10% | ≤15mmHg / Min | 500CC /<6S | ≥180000 |
SV122-4.5 | 4.5 |
≤320 |
≤1.44 |
2.8-5.0V |
16±2 |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
SV122-6 |
6 |
≤200 |
≤1.2 |
4.8-7.2V |
33±10% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
SV122-12 |
12 |
≤117 |
≤1.404 |
10.8-13.2V |
165±10% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
|
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SV131-4.5 | 4.5 |
≤250 |
≤1.125 |
3.5-5.0V | 20±10% | ≤15mmHg / Min | 500CC /<6S | ≥180000 |
SV131-6 | 6 |
≤160 |
≤0.96 |
4.8-7.2V |
45±10% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
SV131-12 |
12 |
≤100 |
≤1.2 |
10.8-13.2V |
275±10% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
SV131-24 |
24 |
≤60 |
≤1.44 |
20.5-25.2V |
1300±40% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
|
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SV144-3.5 | 3.5 |
≤280 |
≤0.98 |
3-4V | 15±2 | ≤15mmHg / Min | 500CC /<6S | ≥180000 |
SV144-4.5 | 4.5 |
≤250 |
≤1.125 |
3.5-5.0V |
20±10% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
SV144-6 |
6 |
≤200 |
≤1.2 |
4.8-7.2V |
36±10% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
SV144-12 |
12 |
≤117 |
≤1.404 |
10.8-13.2V |
150±40% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
SV144-24 | 24 |
≤100 |
≤2.4 |
20.5-25.2V |
615±10% |
≤15mmHg / Min |
500CC /<6S |
≥180000 |
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SVD141-6 | 6 |
≤500 |
≤1.35 |
5.6-7.0V | 15±2 | ≤15mmHg / Min | 1500CC /<6S | ≥180000 |
SVD141-12 | 12 |
≤300 |
≤3.6 |
10.8-13.2V |
50±10% |
≤15mmHg / Min |
1500CC /<6S |
≥180000 |
SVD141-24 |
24 |
≤200 |
≤4.8 |
20.5-25.2V |
220±10% |
≤15mmHg / Min |
1500CC /<6S |
≥180000 |
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SV241R-12 | 12 |
≤200 |
≤2.4 |
10.8-13.2V |
65±10% |
≤15mmHg / Min |
1500CC /<4S |
≥180000 |
SV241R-24 |
24 |
≤120 |
≤2.88 |
20.5-25.2V |
250±10% |
≤15mmHg / Min |
1500CC /<4S |
≥180000 |
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SV341E-12 | 12 |
≤200 |
≤2.4 |
10.8-13.2V |
65±10% |
≤15mmHg / Min |
1500CC /<4S |
≥180000 |
SV341E-24 |
24 |
≤120 |
≤2.88 |
20.5-25.2V |
250±10% |
≤15mmHg / Min |
1500CC /<4S |
≥180000 |
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SV541E-12 | 12 |
≤200 |
≤2.4 |
10.8-13.2V |
65±10% |
≤15mmHg / Min |
1500CC /<4S |
≥180000 |
SV541E-24 |
24 |
≤120 |
≤2.88 |
20.5-25.2V |
250±10% |
≤15mmHg / Min |
1500CC /<4S |
≥180000 |
|
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Leakage | Exhaust Speed | Service Life |
SV24B-12 | 12 |
≤360 |
≤4.32 |
10.8-13.2V | 37±10% | ≤15mmHg / Min | 1500CC /<4S | ≥180000 |
|
|
Model |
Rated Voltage |
Working Current |
Power Consumption |
Working Voltage Range |
DC Resistance |
Medium | Function | Leakage | Exhaust Speed | Service Life |
SVS34-24 | 24 | 20V~ |
≤200mA |
4W | 140±15% | Water, Steam |
2 Way, Normally Closed |
≤3mmHg / Min | ≤3.0S | ≥200000 |
Skoncentruj się na swoich wymaganiach, zaoferuj najlepsze rozwiązanie:
√ Skontaktuj się z nami, jeśli masz wątpliwości
√ Skontaktuj się z nami, jeśli gdzieś trzeba się zmienić
√ Skontaktuj się z nami, jeśli nie ten, którego szukasz
√ Skontaktuj się z nami, jeśli zajmujesz się projektowaniem
Witamy na każde pytanie i zapytanie!
Kategorie o produkcie : Zawór elektromagnesu > Plastikowy zawór elektromagnetyczny
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.